Heavy Equipment Guide Logo

IPAF publishes guidance on avoiding contact with power lines when operating MEWPs

A book sits on a grey table
IPAF's new guidance on mobile elevating work platforms IPAF

The International Powered Access Federation (IPAF) has released new guidance outlining key principles and ways to reduce risks when using mobile elevating work platforms (MEWPs) in the vicinity of power lines, with the aim of helping to reduce electrocution and electric shock incidents. The new guidance is part of IPAF's "High Voltage!" targeted global safety campaign.

The new guidance document, entitled Safe Use of MEWPs in the Vicinity of Power Lines, has been developed by IPAF in collaboration with the IPAF International Safety Committee (ISC) and supporting members and is available to view or download initially in English. After being launched officially at CONEXPO-CON/AGG 2023, and following industry review and consideration of any feedback, the document will be made available in other languages and region-specific versions.

The document can be viewed and downloaded free of charge in digital format and is also available print-ready, allowing organizations to produce co-branded hard copies as required.

"By analyzing data from the past ten years of accident reporting via IPAF's portal, it's evident that incidents involving electrocutions and electric shocks have notably increased since 2015," says Brian Parker, IPAF's Head of Safety & Technical. "One standout statistic is that reported incidents of electrocution are nearly always fatal.

"Working in the vicinity of energized power lines can expose workers to health and safety risks including death by electrocution or electric shock. If a MEWP or its occupants contact energized power lines it can cause instant death, electric shock or other injuries caused directly or indirectly by electricity. Equally serious can be the effect of electricity arcing from the power line to a MEWP and its occupants.

"As with all common causes of accidents involving MEWPs, workplace safety culture and behaviour can play a big part in reducing the number of incidents. Ignorance or lack of awareness of the main underlying risks can lead to complacency and potential exposure to unsafe situations. It was clear that this is another of those all-too-common types of incidents that our industry should be doing much more to understand and eradicate, which nearly always result in serious, life-changing injury or death.

"IPAF has prepared a brand new, comprehensive guidance document, which we hope will assist all those planning, operating, and supervising the use MEWPs in the vicinity of power lines in identifying and understanding the risks. The guide outlines measures that can reduce or mitigate these and in turn reduce the occurrence of incidents involving contact with or arcing from power lines."

IPAF's Safe Use of MEWPs in the Vicinity of Power Lines aims to:

  • Provide information for those who plan and manage MEWP operations.
  • Provide information on the main causes of electrocutions with power lines.
  • Raise awareness of the hazards and risks of working in close proximity to power lines.
  • Provide information on the industry sectors where electrocutions and electric shocks occur.
  • Identify risk control measures and a safe system of work (SSoW) to implement and reduce the number of incidents occurring.
  • Provide general global guidance for those who undertake tasks to prevent incidents from occurring.

"We hope all those who read this document and especially those in person at CONEXPO will let us know their thoughts," adds Parker. "Like all of IPAF's industry safety and technical guidance, this is a ‘living document' and we place huge emphasis on listening and responding to constructive feedback – so I urge people to view and download the document, read and understand it, and share it with colleagues."

Key safety guidances when operating mobile elevating work platforms

Plan thoroughly: Look out and around for power lines in the work area. Conduct a site survey and risk assessment ensuring an SSoW is completed. Correct machine selection is critical. If power lines are in your work area contact the Energy Supply Authority (ESA) before work commences. Ensure operators are briefed prior to work commencing and that they are made aware of any power lines in the vicinity.

Ensure operators are trained: Anyone involved in the safe use of MEWPs must be properly trained on the type of MEWP they are using and must receive machine-specific familiarization. Managers must ensure MEWP operators, supervisors, and spotters are briefed on the SSoW.

Stay outside exclusion zones: An exclusion zone is the prescribed safety envelope around live electric power lines. You must not operate a MEWP where there is potential for any part of it to enter an exclusion zone. Distances for exclusion zones can vary; these must be obtained from the relevant ESA.

Know your rescue plan: If someone has been electrocuted by arcing of electricity or has been in contact with a power line, call the emergency services immediately and call the ESA to have the power turned off and the lines isolated. Observe the "stay, call, wait" protocol.

"This is a comprehensive new document and I trust the powered access industry will find it useful in planning and conducting work at height in the vicinity of power lines," says Peter Douglas, CEO & MD of IPAF. "Our accident data shows there is a particular prevalence of this type of incident in the U.S., so to launch the latest IPAF global safety campaign here at CONEXPO is ideal."